FAA20 Embedded NEXCOM Vocoder
Board Manual
This manual has been prepared for the Federal Aviation Administration.
FA100-00107 (March 2004) Rev 1.0.0 Page 45
SYMPTOM
POTENTIAL
PROBLEMS TROUBLESHOOTING TIPS
sample/packet add/drop (SPAD) events.
SPADs should occur no more frequently
than once every few seconds to a minute.
Identify which queues are affected to locate
the timing port problem source.
Use the MIX/ROUTE commands to setup
loopbacks to isolate the area that is causing
the bad audio.
If the vocoder is in the voice path, check the
vocoder FEC error counter to insure it is not
incrementing, i.e. VOC FEC.
Try lowering or raising the audio levels to
see if the condition improves. Note: While
there are peak detectors on the mixer ports,
audio clipping could occur on the far side of
the rate adapter. The adapter filter may
remove the peak levels, but the audio may
still sound bad.
ERR LED
ON Solid
Large timing offset.
Spurious error.
Flash Configuration
Empty
Check the power up message banner on
COM1 to see if the flash parameter
configuration is empty. If empty, configure
the unit and use the ‘CFG SAVE’ command
to update the flash.
Determine the LED appears solid due to
high number of momentary events or has
been latched on by a spurious event. To do
this, use the command ‘BIT LED4 0’. If this
command clears the condition, a spurious
event occurred (during power up, incidental
events can cause the ERR LED to light.
This is off no concern. If the command does
not clear the LED, used the COUNT
command to see if SPAD events are
occurring.
ERR LED
occasionally
blinks
Small timing offsets
are present
Use the COUNT command to check for
sample/packet add/drop (SPAD) events.
SPADs should occur no more frequently
than once every few seconds to a minute.
Identify which queues are affected to locate
the timing port problem source. For some
system configurations, SPAD events are
normal. See Section 6.2.3.
LANYP LED
Blinks
Audio Level too high
To isolate the signal causing the peak event,
use the PROG command to reassign the
general peak LED to specific mixer port
indicators. Adjust the MIX and/or GAM
settings to fix the high audio level problem.
No serial
port comm.
(COM1/
COM2)
Improper terminal
setup
Failed hardware
The most typical problem may be
incompatible baud rate or hardware flow
control setup. The default setting is 115200
bps,8 data bits,1 stop bit, no parity, and no
flow control.