Net-2000™ VCU Users Manual
Version 4.0, December, 2013
Net-
2000™ VCU Control
ads
h>
Commands to the Net-2000™-VCU can be issued after receiving the prompt. Each time a command is issued to the
Net-2000™-VCU it will respond with a string indicating the command was accepted as “OK” or an error message.
After another prompt is ready to receive a new command. Any newline-terminated string reported by the Net-
2000™-VCU between the time a command is issued and a new command prompt is received indicates an error was
encountered executing the command.
Commands consist of a command word, zero or more arguments, and a newline (which marks the end of the
command). Commands for the serial port interface are listed in the following subsections.
When issuing commands at the "adsh>" prompt the NET-2000™ VCU will respond with "<cmd> OK" (where
<cmd> is the command issued) or an error message if the command fails.
3.7.1.1 VOIP mode command
The VOIP commands start the Net-2000™-VCU to VOIP mode.
adsh> dut voip <args>
where args are
arg format arg name arg values
-v [h,l,2,2r] voice source h=handset, l=4-wire, 2=2-wire, 2r=2-wire wait on ring
-c [e,a,s] channel source e=ethernet, a=RS-422 Asynchronous, s= RS-422 Synchronous
-o [gain]
codec output
gain
0,-3,-6 dB
-p [port] port number for channel source == Ethernet
-d [config]
configuration
data
for VAD, Tone Detection, Noise Suppression, Echo canceller Auto
Gain Control (AGC) and High Pitch Detection (in order) depending
on the vocoder implementation to turn a configuration on use '1' to
turn it off use '0'
For example:
"-d 1 0 0 1 0 0" turns vad ON, echo canceller ON only
-r [vocoder] vocoder and FEC
vocoder type is "AMBE+2", to specify FEC on or off pass in
",<rate_index>"
For example:
"-r AMBE+2t,01" specifies -1 vocoder with no FEC
[ip_addr]
the IP address to
send data to
required only if the channel interface is Ethernet
3.7.1.2 VOIP Mode Command Example
adsh> dut voip -v l -c e -r AMBE+2,00 192.168.24.173
In this example the Net-2000™-VCU starts VOIP Mode using the 4-wire interface for voice and Ethernet for the
channel using the -1 vocoder with FEC enabled. It communicates with the device at ethernet address
192.168.24.173 with the default UDP port (4000).
(Subject to Change) Page 14
DVSI CONFIDENTIAL PROPRIETARY
Comentários a estes Manuais