Net-2000™ VCU Users Manual
Version 4.0, December, 2013
(Subject to Change) Page 64
Upgrade Procedure
Digital Voice Systems, Inc.
The Speech Compression Specialists
8 Upgrade Procedure
Future upgrades to the Net-2000™-VCU’s internal software may become available to provide for additional features
and capabilities or to remedy unforeseen issues. In order to upgrade the Net-2000™-VCU’s internal software the
following equipment is required.
A PC (Windows OS) with network access to the same LAN the VCU is on, and a terminal connected to the VCU
console serial port.
The VCU upgrade image file located on a shared folder on the PC
First. Telnet to the VCU. Open a DOS window and telnet to the VCU using its IP address or host name:
telnet 192.168.1.100
Next, at the adsh> prompt of the VCU console shell, give the VCU access to the shared folder by typing the
following commands:
adsh>mkdir /var/upgrade
adsh>smbmount //<host_name>/<share_directory> /var/upgrade -U<user> -
P<password>
where <host_name> is the PC’s host name and <share_directory> is the name of the shared folder.
Be sure the shared folder on your PC does not require require a user name and password to gain access. When
adding -U<user> and -P<password> to the smbmount command the <user> can be any user name and <password>
can be any password.
Note: The mount only works when using the host_name not the IP address. Also, there is no space between
-U and <user> or –P and <password>
Now change directories to the shared folder on the PC and download the upgrade:
adsh>cd /var/upgrade
adsh>cat <imagefile> | flash - /dev/all
where <imagefile> is the file name of the upgrade image. After the upgrade is loaded into the VCU, reboot it with
the following command.
adsh>shutdown